Drug & Pharmaceutical Series

DR Series High-security commercial and domestic safes

The DR Series is Dominator's range of compliant drug and pharmaceutical safes — designed for clinics, veterinary practices and any environment that stores Schedule 8 drugs. Compact wall-mountable models through to large floor-standing units, all built to satisfy regulatory storage requirements with insurance-grade construction.

ds-3-hero-BF8OhDbU

Why DR Series

Engineered for compliance.

Compliant drug storage

Built specifically for the secure storage of Schedule 8 drugs in clinical, veterinary and pharmaceutical settings. Construction satisfies state regulatory requirements for drug storage.

High insurance ratings

Cash rating $50,000 and insurable valuables rating up to $500,000 — the highest cash-to-size ratio in the Dominator range, reflecting the high-value items typically stored.

Wall and floor mounting

DR-1 and DR-2 include wall and floor mounting provisions, allowing flexible installation in clinical environments where floor space is limited.

Models

Choose your DR Series safe

Dominator DR-1 drug safe

DR-1

With compact sizing and direct locking configuration, the DR-1 is the most cost efficient, compliant drug cabinet. Available with key, combination or electronic digital lock options, the DR-1 is also versatile enough to allow simple day to day operation.

External height
350 mm
Weight
38 kg
Capacity
8 L
Locking bolts
2 × Ø30
Full specifications

Dimensions & Weight

External
350 × 240 × 200 mm
Internal
330 × 205 × 115 mm
Total weight
38 kg
Door weight
10 kg
Body weight
28 kg
Capacity
8 L

Interior Fittings

Shelves
1

Door & Clearance

Door swing angle
145°
Door open height
435 mm
Door open width
420 mm
Side clearance
410 mm
Handle projection
35 mm
Door thickness
10 mm
Body thickness
10 mm
Overall door thickness
80 mm

Locking & Fixing

Locking bolts
2 × Ø30
Fixing bolts
8 × Ø14

Packaged & Shipping

Packaged (H × W × D)
0.37 × 0.28 × 0.28 m
Packaged weight
30 kg
Pack type
Skid

Ratings

Cash rating
$50,000
Insurable valuables
Up to $500,000
Dominator DR-2 drug safe

DR-2

Spacious and functional, the DR-2 provides exceptional value with wall and floor mounting provisions to cater for different installation configurations and can be easily converted to any lock type.

External height
600 mm
Weight
90 kg
Capacity
28 L
Locking bolts
3 × Ø30
Full specifications

Dimensions & Weight

External
600 × 450 × 200 mm
Internal
580 × 415 × 115 mm
Total weight
90 kg
Door weight
25 kg
Body weight
65 kg
Capacity
28 L

Interior Fittings

Shelves
3

Door & Clearance

Door swing angle
140°
Door open height
835 mm
Door open width
615 mm
Side clearance
740 mm
Handle projection
35 mm
Door thickness
10 mm
Body thickness
10 mm
Overall door thickness
80 mm

Locking & Fixing

Locking bolts
3 × Ø30
Fixing bolts
8 × Ø14

Packaged & Shipping

Packaged (H × W × D)
0.74 × 0.6 × 0.28 m
Packaged weight
79 kg
Pack type
Skid

Ratings

Cash rating
$50,000
Insurable valuables
Up to $500,000
At a Glance

DR Series size comparison

All DR Series safes drawn to actual relative scale. DR-1 at 350mm through to DR-4 at 1200mm — designed to suit clinical, veterinary and pharmaceutical applications.

Trust and Insurance

Certifications and Insurance

Independently rated for high-value drug and pharmaceutical storage. Cash rating $50,000 / valuables rating $500,000 — the highest insurance ratio in the Dominator range.

Drug Compliant

Schedule 8 storage compliant

Solid Steel

Heavy-gauge steel construction

Cash Rating

$50,000 AUD

Valuables

$500,000 AUD

Power for Life

Free batteries — included

Best Warranty

Australia's best warranty

5-Year Warranty

Standard across the range

Independently tested burglary protection

DR Series safes are constructed to resist forced-entry attacks while satisfying state regulatory requirements for drug storage. Hardened anti-drill plating around the lock and a relocker that engages if attacked. Wall and floor mounting provisions on smaller models make them suitable for installations where floor space is at a premium.

Insurance ratings (AUD)

DR Series safes carry insurable ratings that your business insurer can use to set sub-limits for the high-value items typically stored:

  • Cash rating: $50,000 across the range
  • Valuables rating: up to $500,000

Where local regulations require specific drug-storage compliance, your dealer can provide documentation for your records and your insurer.

Compliant drug storage with the highest cash-to-size insurance ratio in the Dominator range.

Specifications

The full DR Series lineup

Model External (H × W × D) Internal (H × W × D) Weight Capacity Locking bolts Notes
DR-1 350 × 240 × 200 330 × 205 × 115 38 kg 8 L 2 × Ø30
DR-2 600 × 450 × 200 580 × 415 × 115 90 kg 28 L 3 × Ø30
Specs Detail

Technical Information

Construction

  • Solid steel body and door
  • Locking points: 1 (DR-1, DR-2), 7 (DR-3, DR-4 — discontinued)
  • Hardened anti-drill plating
  • Spring-loaded case relocker

Mounting and installation

  • DR-1, DR-2: wall and floor mounting provisions (4 internal bolt holes)
  • DR-3, DR-4: floor-mount only (8 internal bolt holes — discontinued models)
  • Suitable for clinical, veterinary and pharmaceutical environments

Capacity

  • DR-1: 8L with 1 shelf — compact wall-mount unit
  • DR-2: 28L with 3 shelves — standard clinical safe
  • DR-3: 112L with 5 shelves (discontinued)
  • DR-4: 252L with 4 shelves (discontinued)
Engineering

Construction and Security Features

DR Series safes are engineered to satisfy regulatory drug-storage requirements while resisting forced-entry attacks. Every feature below is standard across the range.

Drug-compliant construction

Built specifically to satisfy state regulatory requirements for Schedule 8 drug storage in clinical and pharmaceutical settings.

Solid steel body and door

Heavy-gauge solid steel construction throughout. Reinforced framework provides strength against forced-entry attacks.

Hardened anti-drill plating

All models include hardened steel anti-drill plating around the lock and a spring-loaded case relocker that engages if attacked.

Wall and floor mounting

DR-1 and DR-2 include both wall and floor mounting provisions for flexible installation in space-constrained clinical environments.

Direct locking on DR-1, DR-2

Single-point direct locking on smaller models — cost-efficient and reliable for the standard clinical drug-cabinet use case.

7-point bolt work on larger models

DR-3 and DR-4 (discontinued) use 7-point handle-driven bolt work for the highest level of forced-entry resistance.

Universal lock footprint

Standardised lock mounting allows easy conversion between key, combination and electronic lock types.

Textured black paint

Durable textured black paint finish suitable for clinical environments.

Screenshot 2026-04-29 at 9.46.12 pm

Available in base mounting

Screenshot 2026-04-29 at 9.46.04 pm

Available in Left & Right Hand Hinge

DR Series safes can be specified left-hand or right-hand hinge. DR-1 and DR-2 include wall mounting provisions; floor mounting is recommended where space allows. Confirm configuration with your dealer at time of order.

Lock Options

Lock Options and Upgrades

Every DR Series model is available in three lock configurations as standard. All lock types use a universal footprint, meaning conversion between types is straightforward for a qualified safe technician.

DS-xD

Tecnosicurezza Pulse Electronic

Tecnosicurezza Pulse 2-user electronic safe lock

Operation

6-digit user codes, 2 user capability standard

Power

9V battery (externally changeable) — covered by Power for Life

Best For

Daily access, multi-user environments, fast entry

DS-xC

Group 2 Combination Dial

Group 2 certified 3-wheel combination

Operation

Precision mechanical dial, 3 number combination

Power

None required — works indefinitely without batteries

Best For

Buyers who value simplicity and longevity, environments with no battery maintenance preference

DS-xK

Ross 700 Key Lock

Ross 700 high-security key lock

Operation

Traditional key-turn mechanism

Power

None required

Best For

Buyers who prefer key-access reliability and don't need to share access frequently.

Note

Highest quality mechanical key lock available — can also be specified as a secondary lock on DS-2, DS-3, DS-4 and DS-5 for increased security cash rating

Upgrade

Secondary Key Lock Upgrade

DR Series safes can be specified with a secondary Ross 700 key lock for layered security where regulations or insurance terms require dual control. Your dealer can provide pricing and documentation.

Universal Lock Footprint

DR Series safes use a universal lock mounting footprint — meaning any of the three lock types can be retrofitted to an existing safe by a qualified safe technician.

Configure

Accessories and Spare Parts

Configure your DR Series safe with the accessories below. All accessories are available through your Dominator dealer at point of order or as retrofits.

Shelves

Additional shelves with fitting clips. Sized to suit the relevant DR Series model.

DR-1SHELF

Shelf and clips to suit DR-1

DR-2SHELF

Shelf and clips to suit DR-2

Mounting Kits

Wall and floor mounting hardware to suit DR-1 and DR-2.

DR-WALLKIT

Wall mounting hardware kit

DR-FLOORKIT

Floor mounting hardware kit

For Specifiers

DS Series Specification Tips

Choose by patient throughput, not just storage volume

DR-1 suits low-volume clinical use; DR-2 is the most common general-practice and veterinary specification with 28L capacity and 3 shelves. Specify based on how many controlled drugs you actively manage, not just total volume.

Wall mount where floor space is limited

DR-1 and DR-2 include wall mounting provisions — useful in compact clinical rooms or veterinary surgeries where floor space is at a premium. Confirm wall-construction load bearing with your installer.

Dual lock for regulatory compliance

Some regulatory frameworks and insurance policies require dual-control access to drug stores. The secondary Ross 700 key lock upgrade satisfies this requirement on DR Series safes.

Lifetime Initiative

Power for Life Free batteries for the lifetime of your safe.

Every DS Series safe with an electronic or biometric lock is covered by our Power for Life initiative. Once a year, you can redeem a free replacement battery at any authorised Dominator dealer — no receipts, no conditions, for as long as you own the safe.

It's our way of making sure your safe stays accessible for decades, not just years.

Power for Life applies across the full range: HS Series, DS Series, GC Series (gun cabinets), FA Series and FX Series.

STEP 01

Receive your e-voucher

After registering your warranty

STEP 02

Visit your dealer once a year

With the voucher on your phone

STEP 03

Walk out with a free battery

Recommended Duracell Procell Alkaline battery

Setup

Installation

What to expect

DR Series safes can be installed by your dealer or a qualified safe installer. DR-1 and DR-2 can be wall- or floor-mounted; the larger discontinued DR-3 and DR-4 are floor-mount only.

Secure mounting is essential — an unmounted drug safe can be removed in minutes by a determined thief. DR Series safes include 4 internal bolt-down provisions on DR-1 and DR-2, and 8 on DR-3 and DR-4.

Installation checklist


  1. 01

    Identify mounting bolt provisions — DR-1 and DR-2 have 4 × internal bolt holes for wall or floor mounting. Confirm hole positions with your dealer before drilling.

  2. 02

    Identify install position with access clearance (allow for door swing and handing)

  3. 03

    Confirm delivery access route (doorways, corridors, stairs)

  4. 04

    Schedule installation through your dealer — most offer delivery + install as a package

  5. 05

    Keep installation certificate for insurance records

Base Anchoring Provisions

Top-view footprint of each DR Series model showing wall and floor anchor bolt positions. All footprints shown to scale relative to each other.

Secondary Defence

Glass Relocker Protection

DR Series safes include a spring-loaded case relocker — a secondary locking mechanism designed to activate if the primary lock is attacked. Understanding how it works helps you know when it’s engaged and what to do if it is.

How it works

A thin glass plate is embedded behind the primary lock body. If a drilling, punch, or torch attack breaks the glass, spring-loaded secondary bolts deploy and jam the locking mechanism. Once activated, the safe cannot be opened even if the primary lock is subsequently bypassed — it requires professional recovery by a qualified safe technician.

The relocker is a permanent protection feature, not a consumable. It exists to make the safe effectively unusable to an attacker even if they partially succeed against the primary lock.

If your relocker activates

If you cannot open your safe and suspect the relocker has engaged (usually after attempted forced entry), contact your Dominator dealer immediately. Do not attempt forced opening — this can cause permanent damage to the safe body.

A qualified safe technician can recover the relocker and restore normal operation. The safe itself remains structurally sound and can usually return to service after a relocker recovery.

Maintenance and Servicing

DR Series safes require minimal maintenance but benefit from occasional service to keep locks and hinges operating smoothly through years of use.

Every 12 months

Battery replacement (electronic/biometric locks)

Redeem your free battery through Power for Life. Replace before low-battery warnings, not after.

Every 12 months

Lock lubrication (mechanical dials)

Apply a drop of lock-grade lubricant to the dial spindle annually. Avoid WD-40 or general-purpose oils — they can gum up precision movements.

Every 12 to 24 months, depending if commercial or domestic use

Professional service

Book a qualified safe technician to inspect hinges, bolt work, and relocker mechanism. Typical service takes 30–60 minutes.

Every 5 years

Seal inspection

Check fire seals (where fitted) for compression and integrity. Replace if damaged.

Support

Troubleshooting

DR Series safes include a spring-loaded case relocker — a secondary locking mechanism designed to activate if the primary lock is attacked. Understanding how it works helps you know when it’s engaged and what to do if it is.

Electronic lock won't open — no response from keypad.

Battery is most likely depleted. Replace the 9V battery and try your code again. Use a brand-new Duracell 9V Alkaline battery only. If the keypad still doesn’t respond, contact your dealer for diagnosis.

Electronic lock responds but rejects correct code.

Mechanical dial won't open — combination correct but bolts don't retract.

Lock is working, but handle does not unlock.

Safe door is difficult to open or close.

Safe is damaged or inoperable after attempted forced entry.

Still Stuck?

Contact your Dominator dealer for support, or call 1300 366 462 for direct assistance.

Pricing and availability through our dealer network.

With dealers across Australia and New Zealand, there's a Dominator specialist near you.

Infinity Safes

Your DR Series Safe. Elevated Beyond Recognition. Bespoke interiors, premium finishes, and watch winders — built on the same proven security platform you trust.

Infinity Safes takes the security platform you’ve chosen and transforms it into something genuinely extraordinary. Custom paint, polished hardware, fitted interiors and bespoke finishes — every element designed, finished, and installed in Perth.

If your DR Series safe is going somewhere it needs to look exceptional — a high-end clinical or veterinary practice — Infinity is the answer.